Direct Antiglobulin Test

DAT, Direct Coombs Test
Core Laboratory & Transfusion Medicine
Transfusion Medicine
Blood
DAT1 - For Adult
DAT2 For Neonate

MS 327 Blood Transfusion Product Request

To determine whether patient's red blood cells have been sensitized in vivo with immunoglobulin, complement or both

Peripheral blood

6 mL


Collect 1 Pink top tube EDTA. Mix well at time of collection
Collection Instructions

Send ASAP to Core Laboratory

Stable for 21 days at 1-6C


24 hours / 7 days

30 mins. Longer if result is positive

30 minutes

Tel #: 416-586-4502
Fax #: 416-586-8504

Please deliver to the Core Laboratory, 11th Floor